PRINT
Lumbar Spine section from L1 to Sacrum and Pelvis hemi Iliac
LDPR1534
LDPR1534
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 330mm
- MaterialSolid foam low density. Disk: soft flexible foam Hemi-Iliac: solid foam
- DeliveryDelivery time upon request
PRINT
Lumbar Spine from L1 to Sacrum with pre-drilled pedicle holes, with sewable spinal cord with dura mater
LDPR1423.8
LDPR1423.8
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 230mm. Diameter pedicle holes: 5.5mm
- MaterialSolid foam Low Density. Disk: soft flexible foam. Spinal Cord: gelling agents. Dura: PE
- DeliveryDelivery time upon request
PRINT
Lumbar Spine from L1 to Sacrum with pre-drilled pedicle holes
LDPR1423
LDPR1423
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 230mm. Diameter pedicle holes: 5.5mm
- MaterialSolid foam Low Density. Disk: soft flexible foam
- DeliveryDelivery time upon request
PRINT
Cervical Spine with vertebrae C1 toT1 with spinal cord and nerves and vertebral arteries
LD9398.6
LD9398.6
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 161mm
- MaterialVertebrae C1 to T1: Solid foam low density, Disk: soft foam, flexible, Arteries: PVC hose, Nerves: PUR
- DeliveryDelivery time upon request
PRINT
Lumbar Spine from L1 to Sacrum with radiopaque coating
LDPR1232.10.9
LDPR1232.10.9
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 230mm
- MaterialSolid foam Low Density. Disk: soft flexible foam
- DeliveryDelivery time upon request
PRINT
Lumbar Spine from L1 to Sacrum
LDPR1232.10
LDPR1232.10
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 230mm
- MaterialSolid foam Low Density. Disk: soft flexible foam
- DeliveryDelivery time upon request
PRINT
Lumbar Spine from T10 to L5
LDPR1212
LDPR1212
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 290mm
- MaterialSolid foam Low Density. Disk: soft flexible foam
- DeliveryDelivery time upon request
PRINT
Lumbar Spine designed specifically for vertebroplasty application with open cell structure, section from T10-L5, and Sacrum with radiopaque coating
LDPR0770.9
LDPR0770.9
- Orientationneutral
- Model Typeintact
- DimensionsLength: 390mm
- MaterialSacrum: Solid foam low density, Vertebrae T10-L5: Cortical low density / open cell cancellous bone, Disk: soft flexible foam
- DeliveryDelivery time upon request
PRINT
Cervical thoracal Spine with occipital bone, vertebrae C1 to T4 with ankylosing spondylitis C6 to T1 and with vertebral arteries
LD9389
LD9389
- Orientationneutral
- Model Typemalunion, pathologic
- DimensionsOverall length: 345mm
- MaterialOcciput: Solid foam, C1 to T4: Solid foam low density, Disc: partial solid not flexible
- DeliveryDelivery time upon request
PRINT
Entire Spine from T2 to L5 Pelvis with muscle multifidus and erector spinae from T2 to Sacrum and soft tissue
LSS9308.2
LSS9308.2
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 650mm
- MaterialVertebrae and Pelvis: Solid foam, LSS cancellous bone density, Disk: soft flexible foam, Muscles and soft tissue: soft foam
- DeliveryDelivery time upon request
PRINT
Entire Spine from T2 to L5 with Pelvis
LSS9308
LSS9308
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 645mm
- MaterialVertebrae and Pelvis: Solid foam, LSS cancellous bone density, Disk: soft flexible foam
- DeliveryDelivery time upon request
PRINT
Solid Sacrum without central nerve canal used for spine models
LD9470
LD9470
- Orientationneutral
- Model Typeintact
- DimensionsWidth: 113mm. Length: 110mm
- MaterialSolid foam low density.
- DeliveryEst. Ready to be shipped within 15 working days
PRINT
Sacrum without central nerve canal
LD9410
LD9410
- Orientationneutral
- Model Typeintact
- DimensionsWidth: 122mm. Length: 119mm
- MaterialSolid foam low density.
- DeliveryEst. Ready to be shipped within 15 working days
PRINT
Cervical Spine, vertebrae C1 to C7 with sewable spinal cord and dura mater
LD9399.8
LD9399.8
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 152mm
- MaterialSolid foam Low Density. Disk: soft flexible foam. Spinal Cord: gelling agents. Dura: PE
- DeliveryDelivery time upon request
PRINT
Cervical Spine from C1 to C7 with vertebral arteries
LD9399.01
LD9399.01
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 152mm
- MaterialSolid foam Low Density. Disk: soft flexible foam
- DeliveryDelivery time upon request
PRINT
Cervical Spine section from C1 to C7
LD9399
LD9399
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 152mm
- MaterialSolid foam Low Density. Disk: soft flexible foam
- DeliveryDelivery time upon request
PRINT
Cervical Spine from C1 to T1 with vertebral arteries and radiopaque coating
LD9398.9
LD9398.9
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 161mm
- MaterialSolid foam Low Density. Disk: soft flexible foam
- DeliveryDelivery time upon request
PRINT
Cervical Spine from C1 to T1 with vertebral arteries
LD9398
LD9398
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 161mm
- MaterialSolid foam Low Density. Disk: soft flexible foam
- DeliveryDelivery time upon request
PRINT
Cervical Spine with occipital bone, vertebrae C1 to T1 and with radiopaque coating
LD9391.9
LD9391.9
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 265mm
- MaterialOcciput: Solid foam, C1 to T1: Solid foam low density, Disk: soft foam, flexible
- DeliveryDelivery time upon request
PRINT
Cervical Spine with occipital bone, vertebrae C1 to T1, sewable spinal cord with dura mater
LD9391.8
LD9391.8
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 265mm
- MaterialOcciput: solid foam, C1 to T1: Solid foam Low Density. Disk: soft flexible foam. Spinal Cord: gelling agents. Dura: PE
- DeliveryDelivery time upon request
PRINT
Cervical Spine with occipital bone, vertebrae C1 to T1
LD9391
LD9391
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 265mm
- MaterialOcciput: Solid foam, C1 to T1: Solid foam low density, Disk: soft foam, flexible
- DeliveryDelivery time upon request
PRINT
Cervical Spine with Occiput, vertebrae C1 to T1 and wooden vice attachment
LD9390
LD9390
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 360mm
- MaterialOcciput: Solid foam, C1 to T1: Solid foam low density, Disk: soft foam, flexible
- DeliveryDelivery time upon request
PRINT
Thoracal Spine from T2 to T9 with radiopaque coating
LD9380.9
LD9380.9
- Orientationneutral
- Model Typeintact
- DimensionsOverall length: 244mm
- MaterialSolid foam Low Density. Disk: soft flexible foam
- DeliveryDelivery time upon request