Showing all 15 results

Show sidebar
Sort by
  • Article Number
  • Top Sellers
  • Novelties
  • Title
  • Price (Low to High)
  • Price (High to Low)
By selecting items, you can choose which products should be printed.
Orientation
Type
Structure
Finishing
PRINT

Shoulder right fractured w/ soft tissue X-ray

X-ray images from PR0716.1 Right Shoulder with scapula, clavicle, fractured humerus, ligaments and soft tissue
  • PR0716.1.XR

  • Orientationright
  • Model Typefractured
  • DimensionsOverall length: 370mm
  • MaterialX-ray images
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Shoulder right fractured w/ soft tissue X-ray file

X-ray PDF file from PR0716.1 Right Shoulder with scapula, clavicle, fractured humerus, ligaments and soft tissue
  • PR0716.1.XRF

  • Orientationright
  • Model Typefractured
  • DimensionsOverall length: 370mm
  • MaterialX-Ray File
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Shoulder right fractured w/ vice attachment, soft tissue a/ 3 ETHIBOND needles

Right Shoulder with scapula including vice attachment, clavicle, fractured humerus, ligaments and soft tissue with intermuscular fascia. Delivered with 3 ETHIBOND needles
  • PR0716.1

  • Orientationright
  • Model Typefractured
  • AO/OTA FX Class11C
  • DimensionsOverall length: 370mm
  • MaterialCortical / hard cancellous bone
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Shoulder right

Right Shoulder with scapula, clavicle, humerus and ligaments
  • 5150

  • Orientationright
  • Model Typeintact
  • DimensionsOverall length: 370mm
  • MaterialScapula, Clavicle: Solid foam Humerus: Cortical / hard cancellous bone
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Foam Coat Shoulder Left

Foam coat open, providing cavity, for the placement assembled left shoulded with vise attachment. Bone model is not included in scope of delivery.
  • PR2016

  • Model Typeintact
  • MaterialPUR Foam
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Shoulder right w/ vice attachment

Right Shoulder with scapula including vice attachment, humerus, glenoid labrum and rotator cuff
  • PR1602.10

  • Orientationright
  • Model Typeintact
  • DimensionsOverall length: 370mm
  • MaterialHumerus: Cortical low density / soft cancellous bone, dense. Scapula: solid foam, Glenoid labrum: RUR, Rotator Cuff: Neoprene
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Shoulder right fractured w/ vice attachment a/ 4 ETHIBOND needles

Shoulder with scapula including vice attachment, fractured humerus, ligaments, tendons and rotator cuff. Delivered with 4 ETHIBOND needles
  • PR0857.0

  • Orientationright
  • Model Typefractured
  • AO/OTA FX Class11C
  • DimensionsOverall length: 350mm
  • MaterialBones: Cortical/soft cancellous bone, dense, Ligaments: rubber, tendons: PVC, Muscles: Neoprene
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Shoulder right fractured w/ vice attachment a/ 6 ETHIBOND needles

Right Shoulder with scapula including vice attachment, fractured humerus, ligaments and rotator cuff. Delivered with 6 ETHIBOND needles
  • LDPR1226.0

  • Orientationright
  • Model Typefractured
  • AO/OTA FX Class11B1
  • DimensionsOverall length: 350mm Drill hole diameter: distal 9mm to proximal 14mm
  • MaterialHumerus: Cortical Low density/soft cancellous dense bone, Scapula: Solid foam, Ligaments: Rubber. Muscles: Neoprene
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Shoulder right fractured w/ vice attachment a/ 3 ETHIBOND needles

Right Shoulder with scapula including vice attachment, clavicle, fractured humerus and ligaments. Delivered with 3 ETHIBOND needles
  • PR0716

  • Orientationright
  • Model Typefractured
  • AO/OTA FX Class11C
  • DimensionsOverall length: 370mm
  • MaterialCortical / hard cancellous bone
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Shoulder right w/ clavicle distal fx, soft tissue a/ vise attachment

Right Shoulder with Scapula, Humerus, fractured Clavicle, Ligaments and soft tissue with intermuscular fascia
  • PR0609.01.1

  • Orientationright
  • Model Typefractured
  • AO/OTA FX Class11C
  • DimensionsOverall length: 370 mm
  • MaterialScapula Clavicula: Solid foam / Humerus: Cortical, hard cancellous bone / Foam coat: PUR soft foam
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Shoulder right w/ vice attachment, soft tissue a/ 6 ETHIBOND needles

Right Shoulder with scapula including vice attachment, clavicle, humerus, ligaments, bicep tendon, axillary nerves and soft tissue with intermuscular fascia
  • PR0720.1

  • Orientationright
  • Model Typeintact
  • DimensionsOverall length: 370mm
  • MaterialScapula/Clavicle: Cortical: Solid foam Humerus: Cortical soft density / low cancellous bone structure
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Shoulder right fractured w/ vice attachment a/ structure

Right Shoulder fractured with scapula including vice attachment, humerus, muscles and various structures
  • PR0719.0

  • Orientationright
  • Model Typefractured
  • DimensionsOverall length: 370mm
  • MaterialHumerus: Cortical and hard cancellous bone, Scapula: Solid foam
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Shoulder left w/ fractured humerus, vice attachment a/ soft tissue

Left Shoulder with scapula including vice attachment, clavicle, fractured humerus, ligaments and soft tissue
  • 5700.02.1

  • Orientationleft
  • Model Typefractured
  • MaterialHard Cortical / cancellous bone
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Shoulder right w/ soft tissue a/ vice attachment

Right Shoulder with scapula including vice attachment, humerus, glenoid labrum, rotator cuff and soft tissue with intermuscular fascia
  • PR1602.1

  • Orientationright
  • Model Typeintact
  • DimensionsOverall length: 370mm
  • MaterialHumerus: Cortical low density / soft cancellous bone, dense. Scapula: solid foam, Glenoid labrum: RUR, Rotator Cuff: Neoprene Foam: PUR
  • DeliveryEst. Ready to be shipped within 15 working days
PRINT

Shoulder left recon w/soft tissue a/vice attachment

Left Shoulder with scapula, clavicle, humerus, ligaments, cancellous humeral head, and cancellous under glenoid fossa. With vice attachment and soft tissue with intermuscular fascia, with radiopaque coating
  • LSH5760.9.1

  • Orientationleft
  • Model Typeintact
  • DimensionsOverall length: 430mm Drill hole diameter: distal 6mm
  • MaterialClavicula: Solid Foam. Humerus with cancellous head. Scapula with cancellous under glenoid fossa.
  • DeliveryEst. Ready to be shipped within 15 working days